Earth fault protection of transformer pdf

Because it does not respond to load current, it offers a significant. These elements are part of the transformer protection in that they limit the accumulated. What is earthing transformer or grounding transformer. Protect and monitor most transformer applications with the powerful sel487e. Measurement of three phase residual current is done either by using core balance current transformer cbct or three cts connected in parallel. Restricted ground fault protection can be a low impedance differential function or a high impedance differential function. It offers up to five threephase restraint inputs, three independent restricted earth fault ref protection elements, and two threephase voltage inputs, all with synchrophasors. What you dont know about ground fault protection can.

The level of protection provided for transformers vary worldwide. The winding ground fault current depends on the grounding impedance value and is also directly proportional to the distance of the fault from the transformer neutral point, since the fault voltage will be directly proportional to this distance. As two system supplies and hence two neutrals can be involved, this gives a maximum fault current of 2000 a. Statistically, 9095% of all system shortcircuits are ground faults so this is an important topic. The transformer windings and connections are protected by an extremely inverse relay and two high set overcurrent relays. In practical, always some amount of current flows in the neutral typically 115 amps depending upon rating of the equipment i. This paper will summarize the key points of restricted earth fault protection. The practices used in ground fault protection are described in. This protection is obtained by using a circuitbreaker equipped with a trip unit that has earth fault protection g or with. Setting example for restricted earth fault protection an example of setting the ref 542plus for restricted earth fault protection will be described in the following section. Standby earth fault relay operation 51n electrical4u.

Ct connection to detect earth faulthow earth fault relay. The suite of overcurrent elements 51, section 8 is generally considered backup transformer protection, or for protection of the bus and backup protection for the feeder relays. The directionality of the earth fault elements is provided by either residual voltageor negative sequence voltage. Jul 31, 2016 prominent earth fault protections are restricted earth fault, standby earth fault, sensitive earth fault protection. Loss of voltage transformer protection 60 common practice on large systems to use two or more vts one used for relays and metering the other used for avr.

Protection and control of supply transformers standard. Restricted earth fault protection for auto transformers r estricted earth fault r e f is a zerosequence current based differential scheme. Oct 02, 2016 3ph transformer differential protection through numerical relays duration. Applications are not limited by ct saturation for external or internal faults. The restricted ground fault function can be used to provide differential protection for such ground faults, down to faults at 5% of the transformer winding. The connection of earth fault relay with the star or delta. When the fault occurs, the shortcircuit currents flow through the system, and this current is returned through the earth or. Pdf a new method of avoiding malfunctioning of the transformer restricted earth fault ref protection is presented. Normally this relay is connected to a ct which is located in the neutralearthing point of a transformer. Stability on external earth fault ef on delta side of stardelta power transformer.

A fault current, referred to as a common mode or zerosequence fault mv, then flows in the protection conductor pe andor in the earth. Transformer protection 1 transformer connections overcurrent protection directional protection of parallel transformers partial differential protection of parallel transformers earth faults on transformer windings unrestricted earth fault protection restricted earth fault protection biased differential protection of 2 and 3 winding transformers. In the ideal condition, the residual current will be zero as all the currents. Scheme consists out of a ring ct core balance ct around the three phase conductors, and the relay connected to the secondary. Thus we place maximum torque line at zero degrees with respect to. Restricted earth fault protection of transformer ref protection. Restricted earth fault protection earth fault is the unintended fault between the live conductor and the earth. Moreover, the practices are the same whether the transformers are attended or not. Analysis of an autotransformer restricted earth fault application normann fischer, derrick haas, and david costello, schweitzer engineering laboratories, inc. Restricted earth fault protection for autotransformers r estricted earth fault r e f is a zerosequence current based differential scheme. The relay will only operate for internal earth faults since the transformer. Medium voltage products technical guide protection. Abstractrestricted earth fault, or zerosequence differential protection, is beneficial in transformer applications. Restricted earth fault protection ref for solidly grounded systems a restricted earth fault protection is typically provided as an addition to the normal transformer differential relay.

The only difference in between the differential protection and ref protection is that, latter protection is more sensitive as compared to the former protection scheme. Earth fault relay is a simple over current relay, but it detects earth fault due to the ct connection. Scope this document introduces the application of restricted earth fault protection in ref 542plus. For the arrangement of supply transformer protection andor transmission line protection for an h busbar. Some requirements are onerous, including the requirement for sensitive earth fault sef protection on 100% underground cable networks. Due to the long lead time for repair of and replacement of transformers, a major goal of transformer protection is limiting the damage to a faulted transformer. In victoria, the victorian service and installation rules vsir describe the statespecific requirements for connecting to the networks of local utilities. For a fault on a transformer secondary winding, the matching primary current will depend on the. However, earth fault currents are intentionally limited to very low levels in high impedance earthed systems. High impedance restricted earth fault protection siemens. An external fault in the star side will result in current flowing in the line current transformer of the affected phase and at the same time a balancing current flows in the neutral current transformer, hence the resultant current in the relay is therefore zero. The most common application of the mref is in the protection of transformer restricted earth fault and is detailed in this note.

Supplied with tecquipments protection and relay test set psl50, the relay enables investigations into protection and monitoring of transformers. Restricted earth fault protectionsafeguarding your power. In this, the fault may be in one phase to ground lg or one or more phase to ground llg or lllg. The current transformer reads the fault current and if the fault current exceeds the preset value, the relay operates.

It compares the incoming and outgoing current from the equipment along the circuit conductor. Introduction transformers are a critical and expensive component of the power system. In that case during an earth fault, a nearly undetectable level of fault current flows, requiring earth fault monitoring with voltage based for example, 3rd harmonic voltage monitoring and fundamental frequency neutral voltage shift monitoring protection relays. Restricted earth fault protection of transformer ref. Directional earth fault protection electrical concepts.

Influence of winding connections and earthing on earth fault current magnitude. The difference between them is that earth fault protection is primarily used for equipment protection where. Restricted earth fault protection of transformer electrical. What is the difference between restricted earth fault and. Nov 17, 2019 restricted earth fault protection of transformer. Pdf a new method of improving transformer restricted earth. Earth fault protection relay is used as a secondary relay which is connected to the current transformers of the object to be. The current transformer ct can be located either at the supply neutral or around the phase conductors. There remains, then, only the protection against short circuits in the transformers or their connections, and external fault backup protection. Sensitive earth fault a core balance ct should be used to drive the sensitive earth fault. Restricted earth fault protection for a transformer with neutral connection.

Normally used on systems where the earth fault current is limited to a very low value. One of the tests for which the low impedance function failed to operate was an earth fault on the hv bushing of the transformer with the hv. The earth fault, very nearer to neutral point of transformer star winding may also be considered as an incipient fault. Earthfault relay rej 521 service and legacy product.

However, the principle may be extended over a much wider range to encompass machine busbar differential protection. Learn the basics of differential protection of transformers duration. Pdf earth fault protection failure in the distribution transformer. In this scheme the ct secondary of each phase of electrical power transformer are connected together as shown in figure 3. If we assume for simplicity that ib ic 0, then 3i 0 and ia are in phase. Protection and control of supply transformers standard figure 1 typical protection arrangement for a supply transformer for information regarding integration of the protection relays to the scada system, refer to the scada system standard. This protection scheme is known globally as restricted earth fault protection. Ref ct selection, setting calculation, ref testing etc. Ground fault is nothing but a fault or contact occurs between the live conductor to groundneutral point. System earthing arrangements in lv are mainly concerned by common mode faults which occur most frequently in loads and cables.

A severe earth fault leads in to a severe short circuit situation but the initiation occurs with a slow and simple earth fault. The sel487e limits transformer damage by responding to internal fault conditions in. Earthfaultprotectioninsubtransmissionsystems coh teslaconsultants chris. O p o o o o o p p in both commercial and industrial. Typical transformer restricted earth fault protection arrangements are shown in section 2. It can be a high impedance type as shown in figure 4 or a biased lowimpedance type. Pdf high impedance restricted earth fault protection.

In an auto transformer where only one earth is present, the direction of the neutral current can be towards the transformer or away from the transformer. In these case ref relay is more sensitive, as it uses the current flowing through the neutral ct. In this article, we will examine the theory and operation of a specific type of power transformer protection. Principle, need, construction and working of the ref protection in transformers. It is a fast acting circuit breaker to shut down the supply when the earth fault occurs within 140th of a second. Restricted earth fault protection is used to provide instantaneous earth fault protection to the transformer, utilizing highimpedance principal. This reference variable is called the polarisation quantity. An external fault in the star side will result in current flowing in the line current transformer of the affected phase and at the same time a balancing current flows in the neutral current. One of the tests for which the low impedance function failed to operate was an earth fault on the hv bushing of the transformer with the hv circuit breaker open. Restricted earth fault ref protection for power transformer. Earth fault means one of the core is being connected or leaked to the earthing or grounding.

The location of the earthing, generator neutrals or transformer also. This indicates that directional unit for ground relay should pickup as ia is in phase with 3i 0. Prominent earth fault protections are restricted earth fault, standby earth fault, sensitive earth fault protection. The earth fault relay must be very sensitive for sensing the fault. This is a unit protection scheme for one winding of the transformer. Though the buchholz relay covers most of the fault but additional protection also must include in transformer protection system. It also occurs, because of the insulation breakdown. If the earthing transformer on the delta side is outsides the zone of protection the earth fault ef in the delta system outside current transformer ct locations would produce current distributions as shown which circulate within the differential ct secondaries and is kept out of operating coils. Differential relay may not be able to sense earth faults in the winding as the fault magnitude may be smaller than the set differential current, id.

Such settings protect a restricted portion of the winding. The power transformer is assumed to have the following technical data. What is difference between earth leakage relay and earth. Protection and control of network transformers standard b nonmandatory standard, or guideline, then this standard will prevail over that standard or guideline. The degree of protection is very much improved by the application of restricted earth fault protection or ref protection. Analysis of an autotransformer restricted earth fault application. The stabilising current is connected in series with the. Hands on relay school transformer protection open lecture.

Principle of operation y 87 x a b equipment to be protected ip ip ra rb s1 s2 s2 s1 if. In a restricted earth fault protection, the cts are connected in a fashion as shown below. In this video we havr explained how earth fault is detected. A restricted earth fault relay would therefore, if no special measures were taken, sense an earth fault current that does not exist on the primary side. Order the sel787 with the slot e card containing the 1 a or 5 a current input for ref protection. This relay protects the delta or unearthed star winding of the power transformer against the fault current. Restricted earth fault protection system explanation. The total fault clearance time is again assumed to be 0. Earth fault protection applied to a deltaconnected or unearthed star winding is inherently restricted, since no zero sequence components can be transmitted through the transformer to the other windings. Sensitive earth fault protection is provided for feeder and motor circuits. The ground fault circuit interrupter is a safety device to prevent an electrical accident when any faulty tool is plugged in. Restricted earth fault ref protection apply the ref protection feature to provide sensitive detection of internal ground faults on grounded wyeconnected transformer windings and autotransformers. Ground fault is nothing but a fault or contact occurs between the live conductor to ground neutral point. In this case, the protective relay of the main circuit breaker of the feeder operates at a time faster than the hrc fuses of the faulty transformer.

In this fault the fault current directly flows to the ground. So this ref relay will not be actuated for external earth fault. Sensitive earth fault protection electrical concepts. An external fault in the star side will result in current flowing in the line current transformer of the affected phase and at the same time a balancing current flows in the neutral current transformer. Earth fault protection an overview sciencedirect topics. Both windings of a transformer can be protected separately with restricted earth fault protection.

In solidly earthed and low impedance earthed systems, high levels of earth fault current result. Medium voltage products technical guide protection criteria. During ground fault say at phase a, 3i 0 flows from ground to neutral of a wye connection of transformer. The term standby earth fault protection i know, is related to a ef relay that operates after all the other ef protection schemes fail to operate.

An output contact matrix allows start or trip signals from the protection stages to be routed to the desired output contact. Analysis of an autotransformer restricted earth fault. The maximum setting of the groundfault protection shall be 1200 amperes, and the maximum time delay shall be one second for groundfault currents equal to or greater than 3000 amperes. Transformer protection and transformer fault electrical4u. Restricted earth fault protection ansiieeeiec code 64g64ref is used as a complement or to replace differential protection for windings faults to earth. In this, the fault may be in one phase to ground lg or one or more phase to ground.

Protection and control of network transformers standard. The relay is designed for sensing the fault current which is 15% more than that of the rated winding current. Electrical safety earth fault protection tutorialspoint. Restricted earth fault ref protection is basically a differential protection. So transformer protection scheme is required for incipient transformer faults also. Groundfault current transformer location 1 a ground fault on a grounded system can be detected using a currentsensitive ground fault monitor.

Modified differential ground fault protection systems 6. Fundamental concepts, design and performance conference paper pdf available june 2016 with 22,981 reads how we measure reads. If there is a zero sequence impedance of transformer, the power and leakage impedance rating of the transformer. Apr 25, 2018 restricted earth fault ref protection is basically a differential protection. Overcurrent relays are used as a backup protection with time delay higher than that for the main protection. The relay is connected to a ct in the neutral point of the transformer and residually connected cts in the phases.

Restricted earth fault protection is utilized for yconnected windings. The earth fault protection function uses conventional current transformer measurement. Restricted earth fault protection is provided in electrical power transformer for sensing internal earth fault of the transformer. The ground fault protection system shall be performance tested when first installed on site. Section 6 provide the primary transformer fault protection. Differential protection has excellent operation in most fault cases, but in the situations that a single phase to ground fault occurs near the neutral point in solidly grounded transformers, the. Jul 12, 20 common faults in transformer open circuit fault, over heating. Transformer protection 1 transformer connections overcurrent protection directional protection of parallel transformers partial differential protection of parallel transformers earth faults on transformer windings unrestricted earth fault protection restricted earth fault protection.

One of the major advantages of the restricted earth fault relays is their high sensitivity. Restricted earth fault protection is designed to detect power transformer earth faults. White paper double ground fault protection implementation. What is standby earth fault relay protection in tamil duration. Restricted earth fault protection is a form of differential protection, typically applied to transformers. Both earth fault protection and earth leakage protection are intended to detect a fault current from a phase conductor to the earth ground. Restricted earth fault ref protection is a sensitive way to protect a zone between. In earlier posts we have already discussed differential protection of transformer and various characteristics of differential protection. An earth fault current is a current that flows to earth and has a magnitude that depends on the method of system earthing. Restricted earth fault protection of transformer an external fault in the star side will result in current flowing in the line current transformer of the. A high magnitude through fault external fault fed by the transformer shakes and heats a transformer winding, and the longer the through fault lasts, the greater the risk of it evolving into an internal transformer fault.

963 876 1101 898 623 599 1366 972 1359 830 51 220 615 540 997 729 397 381 908 1365 980 59 875 265 417 711 435 283 36 96 839 173 739 725 1067 705 314 1174 1100 267 1097 37 558 804 1079